Brand Name : SUPERISYS

Model Number : 16 channel digital input and output series

Certification : ISO\FCC\ROSH

Place of Origin : CHINA

MOQ : one

Price : Large quantity price negotiable

Payment Terms : T/T, Western Union

Supply Ability : 1000 per day

Delivery Time : 1-2 work days

Stock : In Stock

Description : 16 channel digital input and output series

Product description : IP67 protection class

I/O connection mode : M12, 5pin hole holder, A code

Number of IO-Link ports : 1x device

lO-Link deals with data length : Two input bytes

Minimum cycle period : 3 ms

Rated operational voltage : 18…30V DC

Maximum load current (sensor) : 200 mA

Maximum load current (actuator) : 500 mA

Total current UI : <1.6A

Total current UO : <2.5A

IO-LINK RUN : Red: communication interruption

PWR : Yellow: the auxiliary power supply is not connected

I/O : Red: port failure

Shell material : PA6+GF

Shell color : black

level of protection : IP67, epoxy full potting

Boundary dimension : 155mm x53mm x28.7mm

Weight : 217g

Operating temperature : -25°C...70°C

Storage/transport temperature : 40°C...85°C

Operation humidity : 5%...95%

Store/transport humidity : 5%...95%

Operating atmospheric pressure : 80KPa...106KPa

Store/transport atmospheric pressure : 80KPa...106KPa

I/O port tightening torque : M12:0.5Nm

Application environment : In accordance with EN-61131

Vibration measurement : Comply with IEC60068-2

Impact test : Comply with IEC60068-27

Free drop test : Comply with IEC60068-32

Electromagnetic compatibility (EMC) : Comply with IEC61000-4-2,-3,-4

Authentication : CE,RoHS

Mounting hole specification : ∅4.3mm x 4

IO LINK : Point To Point Networking Standard

Contact Now

IACM-DO16P-IOL-V,IOLINK Slave Station,Can Expand 16 Channels Digital Input And Output Series,

Product characteristics

Wide use, long life, high reliability:

Working voltage: 10-30VDC;

Output function: two lines normally open normally closed

With polarity, overload, short circuit protection

Protection level: IP67

Direct outlet type, connector type

Operating temperature -25°C-+70°C

Capacitor switch all series have high and low temperature resistance series

Model IACM-DO16P-IOL-V IACM-DO16P-IOL-VR IACM-DIO16P-IOL-V IACM-DIO16P-IOL-VR
product description IO-LINK slave module
8 x ports
IP67 protection rating
I/O connection mode M12, 5pin socket, code A
IO-Link slave station parameters
Number of IO-Link ports 1x Equipment
lO-Link Processes the data length 2 Output bytes Two input bytes, two output bytes
Minimum cycle 3 ms
Input and output parameters
Quantity of input and output 16-Channel output 16-Way Adaptive
Rated operational voltage 18…30V DC
Maximum load Current (Sensor) - 200 mA
Maximum load current (sensor) 2A
Total current UI - <1.6A
Total current UO <12A
Module indicator
IO-LINK RUN Green: The communication is down
Blinking green: The communication is normal
Red: Communication is interrupted
PWR Green: The power supply to the module is normal
Off: The power supply of the module is not connected
I/O Green: The channel signal is normal
Red: The port is faulty
AUX Green: The auxiliary power supply is normal
Red: Auxiliary power supply is reversed
Off: The auxiliary power supply is not connected
Pin definition of the I/O port
port IACM-DO16P-IOL-V Digital Point To Point Networking Standard IOLINK Slave Station IACM-DO16P-IOL-V Digital Point To Point Networking Standard IOLINK Slave Station
M12
A-code
Female Connector
Address Distribution IACM-DO16P-IOL-V Digital Point To Point Networking Standard IOLINK Slave Station
Data port pin definition
IO-LINK IACM-DO16P-IOL-V Digital Point To Point Networking Standard IOLINK Slave Station
Port
Stitch definition
Underlying parameter
IACM-DO16P-IOL-V Digital Point To Point Networking Standard IOLINK Slave Station Shell material PA6+GF
Shell color Black
level of protection IP67, epoxy full potting
Boundary dimension 155mm×53mm×28.7mm
Weight 227g
Operating temperature -25℃…70℃
Storage/transport temperature -40℃…85℃
Operation humidity 5%…95%
Storage/transport humidity 5%…95%
Operating atmosphere 80KPa…106KPa
Preserve/transport atmospheric pressure 80KPa…106KPa
I/O port tightening torque M12:0.5Nm
Application environment Conforms to EN-61131
Vibration measurement Comply with IEC60068-2
Impact test Comply with IEC60068-27
Free drop test Comply with IEC60068-32
Electromagnetic Compatibility (EMC) Comply with IEC61000-4-2,-3,-4
Authentication CE,RoHS
Mounting hole specification ∅4.3mmx4
Auxiliary power port pin definition
Auxiliary power port Power connection mode M12, 5-core, L-code, Male/female IACM-DO16P-IOL-V Digital Point To Point Networking Standard IOLINK Slave Station
System power supply voltage us 18…30 VDC(type.24VDC)
M12 Auxiliary power supply voltage ua 18…30 VDC(type.24VDC)
L-code Total current Is 12A
Male end Total current la 12A
Static working current Ic ≤150mA
Stitch definition Power reverse protection have
Power port tightening torque M12:0.5Nm


Product Tags:

Digital Point To Point Networking

      

Point To Point Networking Standard

      
Buy cheap IACM-DO16P-IOL-V Digital Point To Point Networking Standard IOLINK Slave Station product

IACM-DO16P-IOL-V Digital Point To Point Networking Standard IOLINK Slave Station Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Superisys (Wuhan) Intelligent Technology Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)